Eaton FI Schutzschalter 40 A 30 mA Typ B
Artikel nr: CH-10-15
Eaton Moeller Residual current circuit-breaker, all-current sensitive, 40 A, 4p, 30 mA, type XG/B
Endast 1 kvar i lager
459,60 €
inkl. moms., plus fraktkostnader
Upskattad leveranstid: 7 Dagar
Kvantitet:
Lägg till i varukorgen
Eaton RCD 40 A 4p 30 mA type XG/B
The go-e Charger is equipped with an integrated DC protection module with DC detection and additional AC detection (6 mA DC, 20 mA AC).
On the building side, an RCD type A must be installed and a miniature circuit breaker must be installed upstream. The local installation regulations must be observed.
GENERAL SPECIFICATIONS
- Product name: Eaton Moeller series xPole - PFIM Type B RCCB
- Part no.: PFIM-40/4/003-XG/B
- Product Length/Depth: 80 millimetre
- Product height: 71 millimetre
- Product width: 70 millimetre
- Product weight: 0.32 kilogram
- Compliances: RoHS conform
- Certifications: IEC/EN 62423, IEC/EN 61008
- Product Tradename: xPole - PFIM Type B
- Product Type: RCCB
- Product Sub Type: None
Basic Information
- Application: Switchgear for residential and commercial applications, xPole - Switchgear for residential and commercial applications
- Number of poles: Four-pole
- Tripping time: Short time-delayed
- Amperage Rating: 40 A
- Rated short-circuit strength: 10 kA
- Fault current rating: 30 mA
- Sensitivity type: All current sensitive
- Impulse withstand current: Surge-proof, 3 kA
- Type: PFIM
- Residual current circuit breakers: Type B
TECHNICAL DATA - ELECTRICAL
- Voltage rating: 230 V AC / 400 V AC
- Rated operational voltage (Ue) - max: 400 V
- Rated insulation voltage (Ui): 440 V
- Rated impulse withstand voltage (Uimp): 4 kV
- Rated fault current - min: 0.03 A
- Rated fault current - max: 0.03 A
- Frequency rating: 50 Hz
- Short-circuit rating: 63 A (max. admissible back-up fuse)
- Leakage current type:B
- Rated residual making and breaking capacity: 500 A
- Admissible back-up fuse overload - max: 40 A gG/gL
- Rated short-time withstand current (Icw): 10 kA
- Surge current capacity: 3 kA
- Test circuit range: 196 V AC - 253 V AC
- Pollution degree: 2
- Lifespan, electrical: 4000 operations
TECHNICAL DATA - MECHANICAL
- Frame: 45 mm
- Width in number of modular spacing: 4
- Built-in width (number of units): 70 mm (4 SU)
- Built-in depth: 70.5 mm
- Mounting Method: Quick attachment with 2 latch positions for DIN-rail IEC/EN 60715, DIN rail
- Degree of protection: IP40, IP54 (with moisture-proof enclosure), IP20
- Terminals (top and bottom): Open mouthed/lift terminals
- Terminal capacity (solid wire): 1.5 mm² - 35 mm²
- Connectable conductor cross section (solid-core) - min: 1.5 mm²
- Connectable conductor cross section (solid-core) - max: 35 mm²
- Terminal capacity (stranded cable): 16 mm² (2x)
- Connectable conductor cross section (multi-wired) - min: 1.5 mm²
- Connectable conductor cross section (multi-wired) - max: 16 mm²
- Terminal protection: Finger and hand touch safe, DGUV VS3, EN 50274
- Busbar material thickness: 0.8 mm - 2 mm
- Lifespan, mechanical: 20000 operations
- Permitted storage and transport temperature - min: -35 °C
- Permitted storage and transport temperature - max: 60 °C
- Climatic proofing: 25-55 °C / 90-95% relative humidity according to IEC 60068-2
Flera produkter som du kanske gillar
KUNDTJÄNST
+43 4276 62400
Mån–fre: 7:00–22:00
Mån–fre: 7:00–22:00
Loading...
Bitte warten