Conextra GmbH - Typo3 Warenwirtschaft Systemadministration - Für Sie gemacht
Bästa råd från experter
Snabb leverans
Upp till 5 års garanti

OK
EATON Jordfelsbrytare 40 A 30 mA typ B
EATON Jordfelsbrytare 40 A 30 mA typ B

Eaton FI Schutzschalter 40 A 30 mA Typ B

Artikel nr: CH-10-15

Eaton Moeller Residual current circuit-breaker, all-current sensitive, 40 A, 4p, 30 mA, type XG/B

Endast 1 kvar i lager

459,60 €
inkl. moms., plus fraktkostnader
Upskattad leveranstid: 7 Dagar

Kvantitet:
Lägg till i varukorgen

Eaton RCD 40 A 4p 30 mA type XG/B

The go-e Charger is equipped with an integrated DC protection module with DC detection and additional AC detection (6 mA DC, 20 mA AC).

On the building side, an RCD type A must be installed and a miniature circuit breaker must be installed upstream. The local installation regulations must be observed.

GENERAL SPECIFICATIONS

  • Product name: Eaton Moeller series xPole - PFIM Type B RCCB
  • Part no.: PFIM-40/4/003-XG/B
  • Product Length/Depth: 80 millimetre
  • Product height: 71 millimetre
  • Product width: 70 millimetre
  • Product weight: 0.32 kilogram
  • Compliances: RoHS conform
  • Certifications: IEC/EN 62423, IEC/EN 61008
  • Product Tradename: xPole - PFIM Type B
  • Product Type: RCCB
  • Product Sub Type: None

Basic Information

  • Application: Switchgear for residential and commercial applications, xPole - Switchgear for residential and commercial applications
  • Number of poles: Four-pole
  • Tripping time: Short time-delayed
  • Amperage Rating: 40 A
  • Rated short-circuit strength: 10 kA
  • Fault current rating: 30 mA
  • Sensitivity type: All current sensitive
  • Impulse withstand current: Surge-proof, 3 kA
  • Type: PFIM
  • Residual current circuit breakers: Type B

TECHNICAL DATA - ELECTRICAL

  • Voltage rating: 230 V AC / 400 V AC
  • Rated operational voltage (Ue) - max: 400 V
  • Rated insulation voltage (Ui): 440 V
  • Rated impulse withstand voltage (Uimp): 4 kV
  • Rated fault current - min: 0.03 A
  • Rated fault current - max: 0.03 A
  • Frequency rating: 50 Hz
  • Short-circuit rating: 63 A (max. admissible back-up fuse)
  • Leakage current type:B
  • Rated residual making and breaking capacity: 500 A
  • Admissible back-up fuse overload - max: 40 A gG/gL
  • Rated short-time withstand current (Icw): 10 kA
  • Surge current capacity: 3 kA
  • Test circuit range: 196 V AC - 253 V AC
  • Pollution degree: 2
  • Lifespan, electrical: 4000 operations

TECHNICAL DATA - MECHANICAL

  • Frame: 45 mm
  • Width in number of modular spacing: 4
  • Built-in width (number of units): 70 mm (4 SU)
  • Built-in depth: 70.5 mm
  • Mounting Method: Quick attachment with 2 latch positions for DIN-rail IEC/EN 60715, DIN rail
  • Degree of protection: IP40, IP54 (with moisture-proof enclosure), IP20
  • Terminals (top and bottom): Open mouthed/lift terminals
  • Terminal capacity (solid wire): 1.5 mm² - 35 mm²
  • Connectable conductor cross section (solid-core) - min: 1.5 mm²
  • Connectable conductor cross section (solid-core) - max: 35 mm²
  • Terminal capacity (stranded cable): 16 mm² (2x)
  • Connectable conductor cross section (multi-wired) - min: 1.5 mm²
  • Connectable conductor cross section (multi-wired) - max: 16 mm²
  • Terminal protection: Finger and hand touch safe, DGUV VS3, EN 50274
  • Busbar material thickness: 0.8 mm - 2 mm
  • Lifespan, mechanical: 20000 operations
  • Permitted storage and transport temperature - min: -35 °C
  • Permitted storage and transport temperature - max: 60 °C
  • Climatic proofing: 25-55 °C / 90-95% relative humidity according to IEC 60068-2

KUNDTJÄNST
+43 4276 62400
Mån–fre: 7:00–22:00
Loading...
Bitte warten